Russian scientists have laid the foundation for a technology that in the future will make it possible to "print" living tissues directly into the patient's body. They developed a two-stage concept for fixing biochernils and proposed a single standard for assessing their adhesion to the body. This is an important step for the development of bioprinting directly on damaged tissue areas. As experts told Izvestia, systematized principles and evaluation criteria can help in the development of biochernils for wound healing, restoration of cartilage and heart tissue. However, for now we are talking about the fundamental justification of the methodology. Before implementing new tools, it is necessary to conduct a full range of preclinical and clinical studies.

Applying biochernils to damaged tissues

Scientists at Sechenov University analyzed the mechanisms by which bioadhesive ("sticky") inks are fixed to tissues and how to properly measure the strength of this bond. The authors systematized the chemical and physical mechanisms of adhesion, and also considered the concept of two-stage fixation. In addition, they proposed a minimum standard for describing tests for fixing biochernils. This is important for the development of bioprinting directly on the damaged areas of the patient's tissues.

лаборатория
Photo: IZVESTIA/Sergey Vinogradov
Izvestia reference

Modern bioprinters make it possible to create three-dimensional structures from bio-ink based on hydrogels with living cells. However, when printing directly on damaged tissues (in situ bioprinting), a separate task arises: the material must be securely held on a wet and mobile surface, and the cells inside it must remain viable.

Without reliable grip, the applied structure may noticeably shift. At the same time, chemical modifications that increase adhesion (adhesion to tissues) change the properties of biochernils. In particular, an increase in viscosity makes printing more difficult and increases the shear stresses that cells are subjected to when the material passes through the nozzle.

In a review, the scientific group of the Institute of Regenerative Medicine showed that the adhesion of biochernils to tissue is almost never provided by a single mechanism. It consists of three components: covalent bonds between functional groups of the material and tissue proteins, weak non—covalent interactions (hydrogen bonds, electrostatic attraction and hydrophobic interactions), as well as physical mechanisms of adhesion - interpenetration of polymer chains and mechanical engagement with the micro-dimensions of the tissue surface.

Covalent bonds provide the greatest strength, but they are irreversible and can impair the compatibility of the ink's hydrogel base with cells. Weak interactions are reversible and are better tolerated by cells, but they are inferior in strength.

лаборатория
Photo: IZVESTIA/Polina Violet

The two-stage bioadhesion concept allows combining the advantages of both types of bonds. Immediately after application, the material is fixed to the wet surface of the fabric due to rapid reversible interactions, primarily hydrogen bonds. This prevents the structure from shifting during printing. Then, covalent bonds are formed within a short time. They strengthen the material itself, the bond between the printed layers, and the boundary between the material and the fabric. This approach allows for the stability of the structure and its successful integration into the fabric.

— It is important not only to deliver living cells to the damaged area, but also to ensure the conditions under which the printed structure stays in place. To do this, it is necessary to find a balance between the strength of the adhesion of the material to the tissue, the mechanical stability of the structure itself and the preservation of cell viability," explained Peter Timashev, director of the Institute of Regenerative Medicine at Sechenov University.

However, the lack of standardized methods for assessing adhesion complicates the process of developing inks and especially confirming their functional properties. The bond strength is measured by various tests: for separation, for shear, for peeling and for pressure rupture. Each of them loads the boundary of the material with the fabric in its own way and reveals different mechanisms of destruction.

Prospects of printing on living tissues

The principles and evaluation criteria systematized in the review can help in the development of biochernils for wound healing, restoration of cartilage and heart tissue. In the future, such systems will not only be able to hold the cellular structure in place, but also serve as a platform for the local delivery of therapeutic agents (growth factors, extracellular vesicles, antimicrobials, etc.). At the same time, we are talking about the fundamental basis of a new technology, which has yet to be finalized for clinical use.

лаборатория
Photo: IZVESTIA/Eduard Kornienko

The questions raised by Sechenov University scientists are crucial for bioprinting on living tissues. Keeping biochernils in the application area and learning how to measure adhesion to tissue so that data from different laboratories can be compared is something without which the method remains a demonstration, Stanislav Petrov, Deputy director of the Institute of Biomedical Engineering at NUST MISIS, told Izvestia.

— The two-stage fixation concept and the proposed adhesion assessment standard provide a practically applicable answer to the second part of the task. We asked ourselves the same questions when we developed our in situ bioprinter complex, and we know from experience how much they determine the suitability of the technology in real work," the expert emphasized.

The value of this work lies precisely in the systematization of the requirements for the fixation of biochernils and ways to verify this fixation, explained Lyudmila Bystritskaya, a specialist in biomaterials and tissue engineering at NTI Helsnet. For developers, such a concept can become a guideline when choosing a composition, although uniform requirements for describing tests are no less useful.

— The value of adhesive strength is difficult to interpret without specifying the type and condition of the fabric, the conditions of moistening, the time after application and the method of applying the load. As for the two-stage concept, this is also important. When printing on living tissue, it is not enough to simply apply the material.: rapid hardening during printing, on the one hand, helps to preserve the shape of the structure, but, on the other hand, limits the penetration of polymer chains into the surface layer of the fabric and the formation of adhesion, — said the specialist.

лаборатория
Photo: IZVESTIA/Sergey Lantyukhov

For example, when applying cellular hydrogel to a wound, it is important that it quickly stops spreading, and further fixation takes place under conditions compatible with cell viability. A two-step commit potentially helps to align these requirements.

The review is published in the journal Bioprinting.